Modbus RTU/TCP to EtherNet/IP Protocol Gateway, Wide Temperature
Advantech

EKI-1242IEIMS-A

Modbus RTU/TCP to EtherNet/IP Protocol Gateway, Wide Temperature

£586.22

1

The EKI-1242EIMS Industrial Protocol gateway not only provides seamless communication between Fieldbus and Industrial Ethernet but also supports different protocol devices. Therefore, the Fieldbus gateway can integrate new and existing Modbus RTU/TCP devices to the EtherNet/IP network. Being able to collect data and exchange data between Modbus RTU/TCP to EtherNet/IP, EKI-1242EIMS is a simple and resource saving way to bring the advantages of fast data transmissions between different devices.

  • Seamless integrate Modbus RTU/TCP and EtherNet/IP or PROFINET or OPC UA communication
  • Built-in real time diagnostic to increase high efficiency of device management
  • Designed for protocol extensibility and adaption
  • Modbus TCP scanner mode supports 64 connections
  • Supports dual power input for power redundancy
  • Mounts on DIN-rail and Wall mount

Need a hand finding what you need?

Feel free to get in touch or give us a call on +44 (0)1949 844 511

Datasheets

Specification

Certification

EMC CE, FCC Class A
EMI EN 55011/ EN 55022 Class A, EN 61000-6-4, FCC Part 15 Subpart B Class A
EMS EN 61000-4-2 (Level 4), EN 61000-4-3 (Level 3), EN 61000-4-4 (Level 4), EN 61000-4-5 (Level 4), EN 61000-4-6 (Level 3), EN 61000-4-8 (Level 4)
Freefall IEC 60068-2-32
Shock IEC 60068-2-27
Vibration IEC 60068-2-6

Environment

Temperature (Max. Operating) 75°C (167°F)
Temperature (Min. Operating) -40°C (-40°F)
Operating Temperature -40 ~ 75°C (-40 ~ 167°F)
Storage Temperature -40 ~ 85°C (-40 ~ 185°F)

Ethernet Communication

Ethernet Standard IEEE 802.3 , 802.3ab , 802.3u
RJ-45 Port Connector Type RJ-45
RJ-45 Port Number 4
RJ-45 Transmission Speed 10/100 Mbps

Protection

Port to Port Isolation Built-in 1.5 KV magnetic isolation
Reverse Polarity Present

Mechanism

Dimensions (W x H x D) 42 x 140 x 95 mm (1.65 x 5.51 x 3.74 in.)
Enclosure (Metal) Metal with solid mounting hardware
Mounting (DIN-rail) Yes
Mounting (Wall) Yes
IP Rating IP30
Weight 0.497 kg

Modbus Communication

Modbus RTU/TCP Functions Support 1,2,3,4,5,6,15,16,23
Modbus RTU/TCP Mode Client

Power

Power Consumption 5.2W (system)
Power Operating Current 0.22 @ 24V ;  0.11 @ 48V
Power Input (DC) 12 ~ 48 VDC

Serial Communication

Data Bits 7, 8
Flow Control XON/XOFF, RTS/CTS, DTR/DSR
Parity None, Odd, Even, Space, Mark
Serial Port Connector Type DB9 male
Serial Port Number 2
RS-232 Yes
RS-422 Yes
RS-485 Yes
Serial Signals RS-232: TxD, RxD, CTS, RTS, DTR, DSR, DCD, RI, GND
Stop Bits 1, 2
Serial Transmission Speed 50 ~ 921.6 kbps, any baud rate setting

Software

EtherNet/IP Class Adaper
EtherNet/IP Max. No. of Connection 32 explicit messaging, 5 implicit messaging
EtherNet/IP Max. Total I/O Data Size Input: 496 bytes
Modbus RTU/TCP Functions Support 1, 2, 3, 4, 5, 6, 15, 16, 23
Modbus RTU/TCP Max. No. of Connections 64 connections
Modbus RTU/TCP Mode Client

Warranty

Warranty Period 5 years

Protocol Support

Modbus TCP Yes
Modbus RTU Yes
EtherNet/IP Yes
Ethernet Yes
Modbus ASCII Yes

Our Manufacturers