Modbus RTU/TCP to EtherNet/IP Protocol Gateway, Wide Temperature
Advantech

EKI-1242IEIMS-A

Modbus RTU/TCP to EtherNet/IP Protocol Gateway, Wide Temperature

£627.08

1

The EKI-1242EIMS Industrial Protocol gateway not only provides seamless communication between Fieldbus and Industrial Ethernet but also supports different protocol devices. Therefore, the Fieldbus gateway can integrate new and existing Modbus RTU/TCP devices to the EtherNet/IP network. Being able to collect data and exchange data between Modbus RTU/TCP to EtherNet/IP, EKI-1242EIMS is a simple and resource saving way to bring the advantages of fast data transmissions between different devices.

  • Seamless integrate Modbus RTU/TCP and EtherNet/IP or PROFINET or OPC UA communication
  • Built-in real time diagnostic to increase high efficiency of device management
  • Designed for protocol extensibility and adaption
  • Modbus TCP scanner mode supports 64 connections
  • Supports dual power input for power redundancy
  • Mounts on DIN-rail and Wall mount

Need a hand finding what you need?

Feel free to get in touch or give us a call on +44 (0)1949 844 511

Datasheets

Specification

Ethernet Communication

RJ-45 Transmission Speed 10/100 Mbps
RJ-45 Port Number 4
RJ-45 Port Connector Type RJ-45

Protection

Port to Port Isolation Built-in 1.5 KV magnetic isolation

Serial Communication

Serial Standard RS-232 / RS-422 / RS-485, software selectable
Serial Port Connector Type DB9 male
Serial Port Number 2
Data Bits 5, 6, 7, 8
Stop Bits 1, 1.5, 2
Parity None, Odd, Even, Space, Mark
Baud Rate 50 bps ~ 921.6 kbps, any baud rate setting
Serial Signals RS-232: TxD, RxD, CTS, RTS, DTR, DSR, DCD, RI, GND

Protocol Support

Modbus RTU Yes
Modbus ASCII Yes
Modbus TCP Yes
EtherNet/IP Yes
PROFINET Yes
OPC UA Yes

Software

Modbus RTU/TCP Mode Client
Modbus RTU/TCP Functions Support 1, 2, 3, 4, 5, 6, 15, 16, 23
EtherNet/IP Class Adaper
EtherNet/IP Max. Total I/O Data Size Input: 496 bytes
EtherNet/IP Max. No. of Connection 32 explicit messaging, 5 implicit messaging
PROFINET Type IO-Device
PROFINET Slot 64

Environment

Operating Temperature -40 ~ 75°C (-40 ~ 167°F)
Storage Temperature -40 ~ 85°C (-40 ~ 185°F)

Mechanism

Dimensions (W x H x D) 42 x 140 x 95 mm (1.65 x 5.51 x 3.74 in.)
Enclosure (Metal) Metal with solid mounting hardware
Mounting DIN-rail, Wall mount
Weight 0.497 kg

Power

Power Input (DC) 12 ~ 48 VDC
Power Operating Current 0.22 @ 24V ;  0.11 @ 48V
Power Consumption 5.2W (system)

Certification

EMC CE, FCC Class A
EMI EN 55011/ EN 55022 Class A, EN 61000-6-4, FCC Part 15 Subpart B Class A
EMS EN 61000-4-2 (Level 4), EN 61000-4-3 (Level 3), EN 61000-4-4 (Level 4), EN 61000-4-5 (Level 4), EN 61000-4-6 (Level 3), EN 61000-4-8 (Level 4)
Freefall IEC 60068-2-32
Shock IEC 60068-2-27
Vibration IEC 60068-2-6

Warranty

Warranty Period 5 years
Need a hand?